Listings

NA2XSY

For installation in ground, water, outdoors, indoors and in cable ducts for power stations, industry, and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. Acc. to VDE 0276-603 cables must be protected against direct sun radiation ...

NA2XS2Y

Single-core, distribution cable for outdoors and indoors use in 3-phase formation. Installation in pipes and ground.  

NA2XS(FL)2Y 64/110 kV

In ground, outdoors, in tubes, in water, indoors and in cable ducts.  

NA2XS(FL)2Y

For installation in ground, water, outdoors, indoors and in cable ducts for power stations, industry, and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or during operation.The water blocking tape avoids water propagation i ...

NA2XS(F)2Y

For installation in ground, water, outdoors, indoors and in cable ducts for power stations, industry and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or during operation. The water blocking tape avoids water propagation i ...

N2XSY

For installation in ground, water, outdoors, indoors and in cable ducts for power stations, industry and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. Acc. to VDE 0276-603 cables must be protected against direct sun radiation. ...

N2XSEY

For installation in ground, water, outdoors, indoors and in cable ducts for power stations, industry, and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. Acc. to VDE 0276-603 cables must be protected against direct sun radiation ...

N2XS2Y

Single-core, distribution cable for outdoors and indoors use in 3-phase formation. Installation in pipes and ground.  

N2XS(FL)2Y 64/110 kV

In ground, outdoors, in tubes, in water, indoors and in cable ducts.  

N2XS(FL)2Y

For installation in ground, water, outdoors, indoors and in cable ducts for power stations, industry and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or during operation. The water blocking tape avoids water propagation i ...

N2XS(F)2Y

Single-core, distribution cable for outdoors and indoors use in 3-phase formation. Installation in pipes and ground.  

6-CYKCYDY

For fixed installation indoors and outdoors, in the ground and concrete where is possible mechanical demage risk. The cables are resistant to UV radiation and flame spread.  

6-CYKCY

For fixed installation indoors and outdoors, in the ground and concrete where is possible mechanical demage risk. The cables are resistant to UV radiation and flame spread.

35-CXEKVCEY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

35-CXEKVCE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

35-CXEKCY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

35-CVXEKVCVE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

35-AXEKVCEY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV, V and VI according to PNE 33 0000-2.  

35-AXEKVCE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground. Cables meet requirements PNE 34 76 25 can be used in environments IV, V and VI according to PNE 33 0000-2.  

35-AXEKCY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

35-AVXEKVCVE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

22-PAS/35-PAS

HV insulated single core cables are intended for overhead lines. The insulated single core cables are resistant to UV radiation.  

22-CXEKVCEY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

22-CXEKVCE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

22-CXEKCY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

22-CVXEKVCVE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

22-AXEKVCEY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

22-AXEKVCE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

22-AXEKCY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

22-AVXEKVCVE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

10-CXEKVCEY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

10-CXEKVCE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

10-CXEKCY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

10-CVXEKVCVE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

10-AXEKVCEY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

10-AXEKVCE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

10-AXEKCY

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.

10-AVXEKVCVE

Single-core, distribution cable for outdoor and indoor use in 3-phase formation. Installation in pipes and ground/air. Cables meet requirements PNE 34 76 25 can be used in environments IV,V and VI according to PNE 33 0000-2.